PSION Spreadsheets for Unit Conversions

Unit conversion tables in the form of Psion 3/3a spreadsheets.
The tables included are probably of most interest to science students or those engaged in chemistry, chemical or nuclear engineering,

Contents: 

Activity.spr		Radioactivity ( rate of disintigration) Area.spr		Area
Density.spr		Density
Dose.spr		Radiation Dose & Dose Equivalent
Energy.spr 		Energy
Heattran.spr		Heat Transfer
Length.spr		Length
Massflow.spr		Mass Flow Rate
Mass.spr		Mass
Power.spr		Power
Pressure.spr		Pressure
SolnConc.spr		Solution Concentration
Specheat.spr		Specific Heat
Temp.spr		Temperature
Thermcon.spr		Thermal conductivity
Velocity.spr		Velocity
Volflow.spr		Volume Flow Rate
Volume.spr		Volume	

To install: 
Copy any or all of the .spr files to a \SPR\ directory on any drive.
The files can be installed to a flash disk but remember to set the file attributes for each file to "read only" (use Psion <T>)   	 

To use:

It couldn't be simpler. As written the spreadsheets are just like a set of conversion tables you would find in a printed manual.Scroll down column B until the cell highlighted is  the units you wish to convert FROM. Then scroll right along that row until the cell highlighted is under the column headed by the units you wish to convert to. The number in the highlighted cell is the conversion factor ( ie multiplier).

So to calculate a conversion:

Scroll down Col B. until the units you wish to convert FROM are highlighted
Enter the number of units you wish to convert in col A. alongside the units in col B. 
The equivalent in all other units are shown in each column as you scroll right along the row. 
Scroll along the same row to the right until the highlighted cell is underneath the column heading of the units you wish to convert TO. 
Read off (or copy) the answer in the highlighted cell.

Additional Points to note:

1.To use the Title bar function on most tables   highlight cell C3 and key <Psion>+<T>.

2.Set the file attributes to read only and the numbers in column A will always be set to 1 when you open the spreadsheet. You should do this anyway if you store the spreadsheets on a flashdisk.

3.IMPORTANT: Some of the conversion tables require you to enter the value of one or more constants in addition to the actual value you wish to convert. 
These are:

DOSE.SPR (Radiation Dose & Dose Equivalent) 
Enter QF (quality factor ) for the type of radiation in cell B2. Default QF=1 for Beta,Gamma and X-rays. QF=10 for alpha radiation and fast neutrons.

SOLNCONC.SPR (Solution Concentrations) requires 3 constants
	Molecular Weight of Solute -cell D2
	Molecular Weight of Solvent-cell E2
	Solution Density           -cell F2

eg for a dilute solution of NaOH in water
	MWt. of Solute (NaOH) = 40
	MWt. of Solvent (H2O) = 18
	Soln. Density         = 1
***********************************************************************
LEGAL DISCLAIMER & WARNING
The originator of these tables makes no claim as to  their accuracy and accepts no liability whatsoever for any damage or loss arising from their use. You make use of the information provided entirely at your own risk.
***********************************************************************

Notify any comments or corrections to 

John Swash  CS101452,1012
24 Sept 1996 